CONDENCIAT CD® Air-cooled condensation units electRicalData CONDENCIAT®CD 150 180 200 240 260 300 360 390 450 520 600 Power circuit Nominal power supply V-ph- 400-3-50 Hz Voltage range V 360-440 Control circuit supply 24 V, via internal transformer Maximum start-up current (Un)(1) Standard unit A 114,2 132,4 141,3 143,7 170,4 209,4 169,4 196,4 240,4 226,2 275,2 Unit with soft starter option A 74,7 86,5 93,8 96,2 114,4 139,8 130,4 155,4 181,4 186,4 215,4 CosinePhi at maximum power(2) 0,83 0,81 0,81 0,83 0,81 0,78 0,83 0,81 0,79 0,81 0,78 Maximumunit power input(2) kW 19,5 22,3 24,5 27,9 31,2 35,8 42,3 45,6 52,5 62,4 71,6 Unitrated current draw (3) A 26,2 30,4 34,6 37,6 44,2 53,8 57,8 64,4 78,8 88,4 107,6 Maximumunit current draw (Un)(4) A 35,6 40,0 43,8 48,6 55,8 65,8 74,3 81,8 96,8 111,6 131,6 Maximum unit current draw (Un-10%) * A 38,0 49,0 51,2 57,8 73,2 79,8 88,1 107,9 117,9 146,4 159,6 Customer standby capacity, unit kW Customer standby on the 24 V control circuit Withstand capacity and short circuit protection See the table "Short circuit current withstand capability" (1)Maximum instantaneous starting current (maximum operating current of the smallest compressor(s) + fan current(s) + locked rotor current of the largest compressor). (2)Input power, compressors + fans at the unit operating limits (evaporation temperature = 15 °C, condensing temperature = 65 °C) and the nominal voltage of 400 V (data given on the unit nameplate) (3)Rated conditions: evaporation temperature = 5 °C, outdoor temperature = 35 °C (4)Maximum unit current draw at maximum unit power input and 400 V (values given on the unit nameplate) * Maximum unit current draw at maximum unit power input and 360 V Short circuit current withstand capability (TN system(1)) CONDENCIAT®CD 150 180 200 240 260 300 360 390 450 520 600 Value without upstream protection Short time (1s) assigned current - Icw - kA eff 3,36 3,36 3,36 3,36 3,36 3,36 5,62 5,62 5,62 5,62 5,62 Allowable peak assigned current - Ipk - kA pk 20 20 20 20 20 15 20 20 15 20 15 Value with upstream protection Conditional short circuit assigned current Icc - kA eff 40 40 40 40 40 40 40 40 40 30 30 Associated Schneider circuit breaker NS100HNS100HNS100HNS100HNS100HNS100HNS100HNS160HNS160HNS250HNS250H Compact range type Reference number(2) 29670 29670 29670 29670 29670 29670 29670 30670 30670 31671 31671 (1)Type of system earthing (2)If another current limiting protection device is used, its time-current trip and I2t thermal stress characteristics must be at least equivalent to those of the recommended Schneider circuit breaker. Contact your manufacturer's representative. CATALOGUE 2021 599 599