EREBATM eH Reversible air-to-water heat pump Simple, reliable, high efficiency heat pump Built-in hydraulic module Nominal heating capacity:4 to 15 kW Equipped withNHC control Nominal cooling capacity:4 to 17 kW 410A Cooling and heating Use The EREBATMHe air-to-water heat pump is designed for The EREBATMHe is also compatible with medium to high heating and cooling applications in new and existing individualtemperature emitters for boiler back up operation. homes and small businesses. TheEREBA He heat pump is installed outdoors in an openTM Wheninstalled alone, the EREBA He is compatible with lowTMarea, ideally as close as possible to the boiler room. to medium temperature emitters (underfloor heating, fan coilEach device is tested in the factory and delivered ready for units, water cassettes, radiators, mixed installations, etc.). operation. Ranges The EREBATMHe range of reversible heat pumps comprises If the heat pump is the only source of heat: 4 single-phase models and 2 three-phase models. Below the equilibrium temperature, heating must be provided Operation in cooling mode with an outdoor temperature of 0by another heating source or using an additional electrical °C to 46 °C. supplyactuated by the EREBA He.TM Operation in heating mode with an outdoor temperature of -20If the heat pump is used for back up operation: °C to 35 °C. it operates down to the equilibrium point (temperature below which the heat pump can no longer keep up with heating requirements); below this point, the heat pump and boiler run alternately (heat pump or boiler). ComplianCe EMC: Electromagnetic Compatibility directive 2014/30/EU RoHS: Restriction of Hazardous Substances directive 2011/65/EU Ecodesign 2009/125/EC Machinery 2006/42/EC CATALOGUE 2021 311 311