DYNACIATTM LG Water chillers Heat pump Technical characteristics DYNACIATTMLG 360 390 450 480 520 600 Heating Standard unit Nominal capacity kW 137 156 172 183 206 230 Full load performances* HW1 COP kW/kW 5,60 5,57 5,49 5,64 5,59 5,56 Nominal capacity kW 131 148 163 174 197 218 HW2 COP kW/kW 4,42 4,43 4,37 4,40 4,48 4,36 Nominal capacity kW 125 140 155 166 189 209 HW3 COP kW/kW 3,58 3,62 3,56 3,60 3,76 3,59 Standard unit SCOP 30/35°C kWh/kWh 6,24 6,28 6,18 6,24 6,24 6,08 Seasonal energy efficiency** HW1 ŋs heat 30/35°C % 242 243 239 242 241 235 SCOP 47/55°C kWh/kWh 5,02 5,05 5,01 4,99 5,14 4,92 HW3 ŋs heat 47/55°C % 193 194 192 192 198 189 Prated kW 143 161 178 191 216 239 Cooling Standard unit Nominal capacity kW 115 130 144 153 172 192 Full load performances * CW1 EER kW/kW 4,78 4,75 4,68 4,81 4,76 4,77 Eurovent class B B B B B B Nominal capacity kW 155 176 196 207 230 262 CW2EER kW/kW 6,17 6,07 5,98 6,20 5,94 6,09 Eurovent class A A A A A A Standard unit SEER 12/7°C Comfort low temp. kWh/kWh 6,05 6,16 6,07 5,91 5,97 5,87 Seasonal energy efficiency** SEPR 12/7°C Process high temp. kWh/kWh 6,92 7,05 6,90 6,69 6,69 6,69 Unit with Low-temperature brine solution SEPR Process medium option -2/-8°C kWh/kWh 4,30 4,45 4,42 4,66 4,72 4,68 Seasonal energy efficiency** temp.*** Part Load integrated values IPLV.SI kW/kW 6,860 6,980 6,900 6,820 6,890 6,820 Sound levels Standard unit Sound power(1) dB(A) 76 77 78 76 77 78 Sound pressure at 10 m(2) dB(A) 44 45 46 44 45 47 Unit with Low Noise option Sound power(1) dB(A) 73 74 75 73 74 75 Sound pressure at 10 m(2) dB(A) 41 42 43 41 42 44 * In accordance with standard EN14511-3:2013. ** In accordance with standard EN14825:2016, average climate *** With EG 30% HW1 Heating mode conditions: Evaporator water inlet/outlet temperature 10 °C/7 °C, condenser water inlet/outlet temperature 30 °C/35 °C, evaporator fouling factor0 m. k/W2 HW2 Heating mode conditions: Evaporator water inlet/outlet temperature 10 °C/7 °C, condenser water inlet/outlet temperature 40 °C/45 °C, evaporator fouling factor0 m. k/W2 HW3 Heating mode conditions: Evaporator water inlet/outlet temperature 10 °C/7 °C, condenser water inlet/outlet temperature 47 °C/55 °C, evaporator fouling factor0 m. k/W2 CW1 Cooling mode conditions: Evaporator water inlet/outlet temperature 12 °C/7 °C, condenser water inlet/outlet temperature 30 °C/35 °C, evaporator fouling factor0 m. k/W2 CW2 Cooling mode conditions: Evaporator water inlet/outlet temperature 23 °C/18 °C, condenser water inlet/outlet temperature 30 °C/35°C, evaporator fouling factor 0 m. k/W2 ηs heat 30/35°C& SCOP 30/35°C Values calculated in accordance with EN14825:2016 ηs heat 47/55°C& SCOP47/55°C Bold values compliant toEcodesign regulation: (EU) No 813/2013 for Heat Pump application SEER 12/7°C 12/7°C& SEPR Values calculated in accordance with EN14825:2016 SEPR -2/-8°C Values calculated in accordance with EN14825:2016 IPLV.SI Calculated as per AHRI standard 551-591(SI). (1) I n dB ref=10-12W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. (2) I n dB ref 20μPa,(A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). Eurovent certified values CATALOGUE 2021 515 515