HYDROCIATTMLW Water chillers Heat pump Electrical data notes High efficiency units for high condensing temperatures LW HE 1328 1528 1928 2128 2328 2628 3028 3428 3828 4228 4628 Power circuit Nominal voltage V-ph-Hz 400-3-50 Voltage range V 360-440 Control circuit 24 V via the built-in transformer Nominalstart-up current(1) Circuit A A 587 587 772 772 772 587 587 772 772 772 772 Circuit B A - - - - - 587 587 587 772 772 772 Single power connection point option A - - - - - 749 757 943 965 986 1004 Maximumstart-up current(2) Circuit A A 587 587 772 772 772 587 587 772 772 772 772 Circuit B A - - - - - 587 587 587 772 772 772 Single power connection point optoin A - - - - - 862 887 1072 1172 1202 1232 Cosine phi Nominal(3) 0,88 0,88 0,84 0,86 0,87 0,87 0,88 0,86 0,85 0,86 0,87 Maximum(4) 0,91 0,92 0,90 0,90 0,90 0,91 0,92 0,91 0,91 0,91 0,91 Total harmonic distortion(4) % 0 0 0 0 0 0 0 0 0 0 0 Maximum power input* Circuit A kW 173 191 252 271 290 173 191 252 252 271 290 Circuit B kW - - - - - 173 191 191 252 271 290 Single powerconnection point option kW - - - - - 346 382 443 504 542 580 Nominal input current(3) Circuit A A 162 171 210 230 250 162 171 210 210 230 250 Circuit B A - - - - - 162 171 171 210 230 250 Single power connection point option A - - - - - 324 342 381 420 460 500 Maximum input current (Un)* Circuit A A 275 300 400 430 460 275 300 400 400 430 460 Circuit B A - - - - - 275 300 300 400 430 460 Single power connection point option A - - - - - 550 600 700 800 860 920 Maximuminput current (Un -10%)(4) Circuit A A 300 330 419 455 476 300 330 419 419 455 476 Circuit B A - - - - - 300 330 330 419 455 476 Single power connection point option A - - - - - 600 660 749 838 910 952 (1)I nstantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature = 30°C/35°C. (2)I nstantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained at operation with maximum unit power input. (3)Values obtained at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature = 30°C/35°C. (4)Values obtained at operation with maximum unit power input. * Values obtained in operation with maximum unit power input. Values given on the unit name plate. 554 554 CATALOGUE 2021