DYNACIATTM LG Water chillers Heat pump Technical characteristics DYNACIATTMLG 080 090 100 120 130 150 180 200 240 260 300 Heating Standard unit Nominal capacity kW 30 35 38 44 51 56 70 77 89 101 114 Full load performances* HW1 COP kW/kW 5,48 5,48 5,44 5,47 5,43 5,45 5,49 5,40 5,46 5,42 5,47 Nominal capacity kW 29 33 36 43 49 54 68 74 85 97 108 HW2 COP kW/kW 4,31 4,33 4,32 4,33 4,37 4,31 4,35 4,30 4,27 4,36 4,29 Nominal capacity kW 28 33 35 41 47 52 65 73 81 93 103 HW3 COP kW/kW 3,57 3,61 3,59 3,58 3,65 3,59 3,55 3,60 3,51 3,68 3,54 Standard unit SCOP 30/35°C kWh/kWh 5,35 5,33 5,24 5,28 5,23 5,26 5,95 5,9 5,93 6,01 6,03 Seasonal energy efficiency HW1 ** ηs heat 30/35°C % 206 205 202 203 201 202 230 228 229 232 233 SCOP 47/55°C kWh/kWh 4,31 4,31 4,29 4,31 4,33 4,28 4,79 4,83 4,74 4,96 4,81 ηs heat 47/55°C % 164 164 163 164 165 163 184 185 181 191 184 HW3 Prated kW 32 37 40 47 54 59 75 83 93 106 118 Energy labelling kW/kW A++ A++ A++ A++ A++ A++ - - - - - Cooling Standard unit Nominal capacity kW 25 29 32 37 42 47 58 63 74 84 94 Full load performances* CW1 EER kW/kW 4,68 4,68 4,65 4,68 4,65 4,67 4,65 4,57 4,62 4,58 4,62 Eurovent class B B B B B B B C C C C Nominal capacity kW 34 39 43 50 57 66 78 86 102 113 129 CW2EER kW/kW 6,35 6,04 5,96 5,98 5,83 5,99 6,02 5,83 6,10 5,86 6,08 Eurovent class A A A A A A A A A A A Standard unit SEER 12/7°c Comfort low temp. kWh/kWh 4,79 4,78 4,69 4,72 4,69 4,72 5,41 5,34 5,31 5,45 5,41 Seasonal energy efficiency** SEPR 12/7°c Process high temp. kWh/kWh 6,33 6,34 6,17 6,12 6,16 6,20 6,47 6,33 6,33 6,43 6,47 Unit with Low-temperature SEPR Process medium brine solution option -2/-8°C kWh/kWh 3,88 4,22 4,38 4,29 4,41 3,96 4,10 4,63 4,46 4,67 4,65 Seasonal energy efficiency** temp.*** Part Load integrated values IPLV.SI kW/kW 5,8405,8505,7605,7805,7705,8206,5806,6806,5606,810 6,720 Sound levels Standard unit Sound power(1) dB(A) 67 69 69 69 70 70 72 72 72 73 73 Sound pressure at 10 m(2) dB(A) 36 37 38 38 39 39 40 41 41 42 42 Unit with Low Noise option Sound power(1) dB(A) 65 66 66 67 68 68 68 69 69 69 70 Sound pressure at 10 m(2) dB(A) 34 35 35 35 37 37 37 37 38 38 39 * In accordance with standard EN14511-3:2013. ** In accordance with standard EN14825:2016, average climate *** With EG 30% HW1 Heating mode conditions: Evaporator water inlet/outlet temperature 10 °C/7 °C, condenser water inlet/outlet temperature 30 °C/35 °C, evaporator fouling factor0 m. k/W2 HW2 Heating mode conditions: Evaporator water inlet/outlet temperature 10 °C/7 °C, condenser water inlet/outlet temperature 40 °C/45 °C, evaporator fouling factor0 m. k/W2 HW3 Heating mode conditions: Evaporator water inlet/outlet temperature 10 °C/7 °C, condenser water inlet/outlet temperature 47 °C/55 °C, evaporator fouling factor0 m. k/W2 CW1 Cooling mode conditions: Evaporator water inlet/outlet temperature 12 °C/7 °C, condenser water inlet/outlet temperature 30 °C/35 °C, evaporator fouling factor0 m. k/W2 CW2 Cooling mode conditions: Evaporator water inlet/outlet temperature 23 °C/18 °C, condenser water inlet/outlet temperature 30 °C/35°C, evaporator fouling factor 0 m. k/W2 ηs heat 30/35°C& SCOP 30/35°C Values calculated in accordance with EN14825:2016 ηs heat 47/55°C& SCOP47/55°C Bold values compliant to Ecodesign regulation: (EU) No 813/2013 for Heat Pump application SEER 12/7°C 12/7°C& SEPR Values calculated in accordance with EN14825:2016 SEPR -2/-8°C Values calculated in accordance with EN14825:2016 IPLV.SI Calculated as per AHRI standard 551-591(SI). - Not applicable (1) I n dB ref=10-12W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. (2) I n dB ref 20μPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). Eurovent certified values CATALOGUE 2021 513 513