AQUACIATPOWER TM LD Water chillers availableoptions Options Description Advantages LD ST / HE 602-2000 Medium temperature brine Low temperature chilled water production down to 0 °C Covers specific applications such as ice storage and solution with ethylene glycol and propylene glycol. industrial processes ● Low temperature brine solution Low temperature chilled water production down to -15 °C Covers specific applications such as ice storage and 602 to 1500 with ethylene glycol and -12°C with propylene glycol. industrial processes Unit equipped with specifics variable-speed fans : XtraFans (See specific chapter for maximum available Ducted fan discharge, optimised temperature control, XtraFan static pressure according to size), each fan equipped based on the operating conditions and system All HE version with a connection flange & sleeves allowing the characteristics connection to the ducting system. Low Noise Aesthetic and sound absorbing compressor enclosure Noise level reduction ● Xtra Low Noise Aesthetic and sound absorbing compressor enclosure Noise emission reduction at reduced fan speed associated with low-speed fans ● Protects the inside of the electrics box from dust, IP54 control box Increased leak tightness of the unit water and sand. In general this option is recommended ● for installations in polluted environments Protection grilles Metal gres on the 4 unit sides.ill Improves protection against intrusion to the unit interior, coil and piping protection against impacts. ● Soft Starter Electronic starter on each compressor Reduced start-up current ● Variable speed fans for winter AC fan control using a variable speed control. One Stable unit operation when the air temperature is operation cooling mode down inverter on each refrigerant circuit between 0 °C and -20 °C. ALL ST version to -20 °C Water exchanger frost Electric heater on the water exchanger and the water Water exchanger module frost protection between 0 °C protection piping and -20 °C outside air temperature ● Exchanger and hydraulic Electric heater on the water exchanger hydraulic Water type heat exchanger and hydraulic module frost ALL units with pump module frost protection module and optional expansion tank protection down to an outdoor air temperature of -20 °C option Exchanger and hydraulic Electric heater on the water exchanger hydraulic Water type heat exchanger and hydraulic module frost ALL with water buffer module frost protection module and optional expansion tank & water buffer tankprotection down to an outdoor air temperature of -20 °C tank Utni equipped with one desuperheater on each Production of free high-temperature hot-water Partial heat recovery refrerant circuitig simultaneously with chilled water production ● (or hot water for heat pump) Unit equipped with supplementary water outlet Master/slave operation temperature sensor kit (to be field installed) Optimised operation of two units connected in parallel allowing master/slave operation of two units operation with runtime balancing ● connected in parallel Shell and tube Evaporator covered with an aluminium jacket for evaporator aluminium thermal insulation protection Improved resistance to aggressive climate conditions 602 to 1000 insulation Compressor suction and Shut-off valves on the compressor suction and Simplified maintenance. Possibility to store the discharge valves discharge piping refrigerant charge in the cooler or condenser side ● during servicing Shut-off valves on the compressor Simplified maintenance. Possibility to store the Compressor discharge valves discharge piping refrigerant charge in the condenser side during ● servicing Single high-pressure water pump, water filter, electronic HP single-pump hydraulic water flow control, pressure transducers. For more module details, refer to the dedicated chapter (expansion tank Easy and fast installation (plug & play) 602 to 1500 not included). Option with built-in safety hydraulic components available.) Dual high-pressure water pump, water filter, electronic HP dual-pump hydraulic water flow control, pressure transducers. For more module details,refer to the dedicated chapter (expansion Easy and fast installation (plug & play) 602 to 1500 vessel not included; option with built-in safety hydraulic components available) ● ALL MODELS Refer to the selection tool to find out which options are not compatible. CATALOGUE 2021 421 421