ISPK Modular compact heat pumps Options Options for the outdoor module Corrosion Outdoor environment nCoil with copper pipes and copper fins. nINERA® coil with copper pipes and fins of an aluminium alloy, Corrosion of high performance and great resistance to the corrosion. nCoil with copper pipes and copper fins. Coil with copper pipes and aluminium fins with polyurethane n nINERA® coil with copper pipes and fins of an aluminium alloy, and Blygold® coating(indoor unit and/or hot water coil). of high performance and great resistance to the corrosion. Condensates drain pan in stainless steel. n nCoil with copper pipes and aluminium fins with polyurethane and Blygold® coating. Humidity Comfort / heating options nTropicalised electric panel. n Hot water auxiliary coil, with three-way valve and proportional nTropicalised motors and fans (please consult). control. If the unit includes hot water coil and free-cooling, and works Installation with negative temperatures of outdoor air, an anti-freeze thermostat as safety system is mandatory. nAntivibration mounts made of rubber. n Electrical heaters with assembly in two stages and nService valves for cooling connections and refrigerant charge, proportional control. when the unit is supplied for installation as split version. nOil separator for cooling connections with maximum equivalent length of the cooling line greater than 50 Comfort / indoor air quality options metres, optional only available when the units are supplied in 2 modules, outdoor module and indoor module for n Filtration of the supply air: installation as split version. Gravimetric filter G4. • nPosition of air supply of the outdoor unit: Gravimetric filter G4 + creased opacimetric filters M6 to • •Lateral: by default F9. •Upper: onlyaaiable when the units are supplied for Classification of the filters according to the new ISO 16890 installation as split version. Standard: nGravimetric filters in the return air. The filters frame is •G4 → ISO Coarse 60% removable, and upon request, it is possible to supply the frame separately with the unit SP, to be joined on site (width •M6 → ISO ePM10 60% = 53 mm) •F7 → ISO ePM1 50% •F8 → ISO ePM1 65% Acoustic •F9 → ISO ePM1 80% nAcoustic insulating cover for compressor. n Air quality sensor to enable measuring CO for installation in the environment2 Electric panel or duct-mounted (attached picture) nElectrical power supply with neutral. nEnergy meter for monitoring of the Security power consumption of the installation. Differential pressostat for the detection of clogged filters. n Available if the unit does not Smoke detecting station in accordance with the NF S 61-961 n incorporate electrical heaters (optional upon request). standard. nRefrigerant leak detector (inppm). This allows prompt identification of gas leaks, guaranteeing the safety of any Options for the indoor module people in the vicinity. This detector allows the number of periodic Outdoor environment revisions to the unit to be reduced. Humidity nStop-drop in the indoor air coil. Recommended in cases where a high moisture content in the air is foreseen or when Installation the air flow is high. nAntivibration mounts made of rubber nStop-drop in the outdoor air intake. nPosition of supply and/or return of the indoor unit air. 272 272 CATALOGUE 2021