DYNACIATTM LG Water chillers Heat pump Available options Options Description Advantages LG Low-temperature brine Low temperature glycol solution production down to -12°C with Covers specific applications such as ice storage and solution ethylene glycol industrial processes ● Soft Starter Electronic starter on each compressor Reduced start-up current ● Unit equipped with supplementary water outlet temperature Optimised operation of two units connected in parallel Master/slave operation sensor kit (to be field installed) allowing master/slave operationoperation with operating time equalisation ● of two units conneced in parallelt Evap. single pump Unit equipped with an electrical power and control circuit for Quick and easy installation: the control of fixed speed Sizes 360 to 600 power/control circuit one pump evaporator side pumps is embedded in the unit control Cond. single pump Unit equipped with an electrical power and control circuit for Quick and easy installation: the control of fixed speed Sizes 360 to 600 power/control circuit one pump condenser side pumps is embedded in the unit control Condenser insulation Thermal condenser insulation Minimizes thermal dispersions condenser side (key option for heat pump or heat recovery applications) ● Single high-pressure water pump, water filter, electronic water HP single-pump hydraulic flow control, pressure transducers. For more details, refer toh Easy and fast installation (plug & play) Sizes 360 to 600 module thde edicated capter (expansion tank not included). Option with built-in safety hydraulic components available.) Evaporator hydraulic module equipped with low pressure fixed- speed pump, drain valve, air vent and pressure sensors. For LP evap. single-pump more details, refer to the dedicated chapter (expansion tank Easy and fast installation (plug & play) ● not included. Option with built-in safety hydraulic components available) Evaporator hydraulic module equipped with high-pressure Easy and fast installation (plug & play), variable-speed pump, drain valve, air vent and pressure HP evap. variable-speed sensors. For more details, refer to the dedicated chapter significant pumping energy cost savings single-pump (more than two-thirds), tighter water flowcontrol, ● (expansion tank not included. Option with built-in safety improved sytem reliability hydraulic components available) Dual high-pressure water pump with variable speed drive Easy and fast installation (plug & play), HP VSD dual-pump (VSD), pressure transducers. Multiple possibilities of water significant pumping energy cost savings flow control. For more details, refer to the dedicated chapter Sizes 360 to 600 hydraulic mod. (expansion tank not included; option with built-in hydraulic (more than two-thirds), tighter water flowcontrol, safety components available) improved sytem reliability Evaporator hydraulic module equipped with low -pressure Easy and fast installation (plug & play), variable-speed pump, drain valve, air vent and pressure LP VSD single-pump sensors. For more details, refer to the dedicated chapter significant pumping energy cost savings Sizes 360 to 600 (expansion tank not included.Option with built-in safety (more than two-thirds), tighter water flowcontrol, hydraulic components available.) improved sytem reliability Lon gateway Bi-directional communication board complying with Lon Talk Connects the unit by communication bus to a building protocol management system ● Bi-directional high-speed communication using BACnet Easy and high-speed connection by Ethernet line to a Bacnet over IP protocol over Ethernet network (IP) building management system. Allows access to multiple ● unit parameters Control box for communication with the drycooler via a bus. Permits the use of an energy-efficient plug-and-play Specific dry cooler control For OPERA drycooler need to select the cabinet with option system ● control cabinet manage by the chiller Connect'Touch control External boiler Extended remote control capabilities to a boiler management Control board factory-installed on the unit to control a boiler on/off command. ● Permits easy control of a basic heating system Electric heaters Control board factory-installed on the unit with additional Extended remote control capabilities to up to management inputs/outputs in order to manage up to 4 external heating 4 electric heaters. Permits easy control of a basic heating ● stages (electric heaters, etc.) system Compliance with Russian EAC certification Compliance with Russian regulations regulations ● Insulation of the evap. in/ Thermal insulation of the evaporator entering/leaving Prevents condensation on the evaporator out ref. lines refrigerant lineswith flexible, UV resistant insulation entering/leaving refrigerant lines ● Low noise level Compressor sound enclosure Reduced sound emissions ● Evaporator screw Evaporator inlet/outlet screw connection sleeves Allows unit connection to a screw connector connection sleeves (kit) ● Condenser screw Condenser inlet/outlet screw connection sleeves Allows unit connection to a screw connector connection sleeves kit ● HP single-pump, Condenser hydraulic module equipped with high pressure condenser side fixed-speed pump, drain valve, air vent and pressure sensors. Easy and fast installation (plug & play) Sizes 360 to 600 Built-in safety hydraulic components available in option. ● ALL MODELS Refer to the selection tool to find out which options are not compatible CATALOGUE 2021 511 511