AQUACIATPOWER TM LD/ILD Water chiller & heat pump availableoptions Options Description Advantages LD ILD Dual low pressure water pump, water filter, electronic water flow control, pressure LP dual-pump sensors. For more details, refer to the Quick and easy installation (plug & play) 0602R-1400R hydronic module dedicated chapter (expansion tank not ● included; option with built-in hydraulic safety components) Evaporator hydronic module equipped with a Quick and easy installation (plug & play), high pressure variable-speed pump, drain significantreduction in pumping energy HP evap. variable-valve, air vent and pressure sensors. For more consumption level (more than two-thirds), speed single-pumpdetails, refer to the dedicated section ● ● (expansion tank not included; option with precise water flow control, improved system built-in hydraulic safety components available.) reliability Dual high pressure water pump with speed Quick and easy installation (plug & play), HP VSD dual- regulator, pressure sensors. Multiple variablesignificant reduction in pumping energy pump hydraulic water flow control options. For more details,consumption level (more than two-thirds), ● ● mod. refer to the relevant section. precise water flow control, improved system reliability High nominal Higher air flow through the condenser coils Energy cost reduction and extended energy efficiency improving heat exchange efficiency on the operating envelope (full load operation at ● ● condenser higher air temperature) High seasonal Unit equipped with variable-speed fans Enhances the unit seasonal energy efficiency energy efficiency (VSD) performance and reduces the noise emission 0602R-1400R ● (VSD) thanks to a smooth fan speed variation. High seasonal Enhances the unit seasonal energy efficiency energy efficiency Variable-speed fans with EC motors performance and reduces the noise emission ● ● (EC) thanks to a smooth fan speed variation. Lon gateway Two-directional communication board Connects the unit by communication bus to a complying with Lon Talk protocol building management system ● ● Two-directional high-speed communication Easy, high-speed connection by Ethernet line Bacnet over IP using BACnet protocol over Ethernet to a building management system. Allows ● ● network (IP) access to multiple unit parameters Energy EMM Control board with additional Extended remote control capabilities Management inputs/outputs. See Energy Management (Setpoint reset, ice storage end, demand ● ● Module Module option chapter limits, boiler on/off command...) Contact for 0-10 V signal to report any refrigerant Immediate customer notification of refrigerant refrigerant leak leakage in the unit directly (the leak detector losses to the atmosphere, allowing timely ● ● detection itself must be supplied by the customer) corrective actions Compliance with Russian EAC certification Compliance with Russian regulations ● ● regulations Coil defrost Electric heaters under the coils and the Prevents frost formation on the coils; resistance heaterscondensate pans compulsory in heating mode if the outdoor No ● temperature is below 0 °C Insulation of the Thermal insulation of the evaporator Prevents condensation on the evaporator evap. in/out ref. inlet/outlet refrigerant lines, with flexibleentering/leaving refrigerant lines ● ● lines and UV-resistant insulation Coating by conversion process which modifies the surface of the aluminium MCHE producing a coating that is integral to the Protect2 Improved corrosion resistance of the anti-corrosion coil. Complete immersion in a bath to ensure MCHE coils by 2, recommended for use in ● No protection Protect2100% coverage. No heat transfer variation, moderately corrosive environments salt spray resistance test for 4000 hours (ASTM B117) Extremely durable an flexible epoxyd polymer coating applied on micro channel MCHE coils by electro coating process, final UV Protect4 Improved corrosion resistance of the anti-corrosion protective topcoat. Minimal thermal transfer MCHE coils by 4, recommended for use in ● No protection Protect4variation, tested 6000 hours constant neutral corrosive environments salt spray per ASTM B117, superior impact resistance per ASTM D2794 Flanged Victaulic piping connections with flanged evaporator water joints Easy installation ● ● connection kit Compressor Improved aesthetics, compressor protection enclosure Compressor enclosure against external elements (dust, sand, ● ● water…) ● ALL MODELS Refer to the selection tool to find out which options are not compatible. 394 394 CATALOGUE 2021