VECTIOS™ PJ Compact air-air rooftop units Model number nomenclature IPJ_0090 A 3 U C0 AA 000 0 N B E 0 00000000000 0 0 T100 00 P00 000C10000000000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24 25 Group 1: Unit type • J: G4 + F9 + stop-drop • RPJ: air/air cooling units • K: G4 l.p.d. + F7 1: 1 sensor RS485 • IPJ: air/air heat pump • L: G4 l.p.d. + F7 + stop-drop 2: 2 sensors RS485 • M: G4 l.p.d. + F9 3: 3 sensors RS485 Group 2: Unit model N: G4 l.p.d. + F9 + stop-drop 4: 4 sensors RS485 • •1 circuit: 0090 / 0120 / 0140 / 0160 / 0180 / 0190 • O: M6 + F7 5: 1 sensor NTC •2 circuits: 200 / 0220 / 0240 / 0280 / 0320 / 0360 • P:M6 + F7 + stop-drop T: Ambient temperature sensor / 0380 Q: M6 + F9 H: Ambient temperature+humidity sensor • Group 3: Version of the series • R: M6 + F9 + stop-drop P: Ambient sensor on the pLAN network • S: F7 + F9 Group 4: Electrical power T: F7 + F9 + stop-drop Group 20: Free-cooling + Outdoor humidity • • 3: 400V / 3ph + N / 50Hz • U: F9 + F9 00 Without free-cooling + without sensor •4400V / 3ph / 50Hz: • V: F9 + F9 + stop-drop 1: Outdoor humidity sensor on the unit Group 5: Type of refrigerant Group 12: Type of outdoor fan 2: Outdoor humidity sensor on pLAN network U: R410A A: AC (2-speed) T: Thermal free-cooling • • M: Thermoenthalpic free-cooling Group 6: Air flow + Assembly • E: EC (electronic) E: Enthalpic free-cooling •C0: Cross flow with standard assembly Group 13: Insulation Group 21: Terminal + Unit communication •CS: Cross flow with 2 dampers • 0: Standard insulation CF: Cross flow 100% fresh air 1 Insulation Euroclass A2-s1, d0 (M0): 000 Without terminal + stand-alone + without card • • CK: Cross flow with 3 dampers M: Communication card RS485 Modbus/Carel • Group 14: Indoor unit configuration CA: Cross flow with axial return fan E: Communication card Ethernet PCoWeb • 000 Without optional accessories CP: Cross flow with lower return plug-fan L: Communication card RS485 LonWorks® • A: Condensate drain pan in stainless steel CR: Cross flow with lower return plug-fan and active B: Communication card Ethernet BACnetTM • 1: Overpressure management recovery C: Communication card RS485 BACnetTM CQ: Cross flow with upper return plug-fan or pressostatA: Clogged filters K: Communication card RS485 Konnex • centrifugal fan Group 15: Outdoor unit configuration 0: Free-standing unit •CT: Cross flow with upper return plug-fan or0000 Without optional accessories 1: Master unit centrifugal fan and active recovery A: Fresh air intake protection grid 2: Slave unit •CW: Cross flow with passive recovery 1: Outdoor coil protective grille P: VecticGD terminal in electrical cabinet •T0: Tunnel flow with standard assembly A: Antivibration mounts T: TCO user terminal in electrical cabinet •TS: Tunnel flow with 2 dampers 1:Stop-drop at the fresh air intake R: VecticGD terminal in electrical cabinet + •TP: Tunnel flow with return plug-fan TCO terminal remote up to 100 m •TW: Tunnel flow with passive recovery Group 16: Passive recovery S: TCO terminal in electrical cabinet + Group 7: Coil coating : Indoor - Outdoor 0000 Without optional accessories VecticGD terminal remote up to 200 m AA Indoor coil - Outdoor coil 1: Filters G4 (fresh air intake) N: VecticGD terminal in electrical cabinet + A: Aluminium A: Aluminium 2: Filters G4 l.p.d. (fresh air intake) VecticGD terminal remote up to 200 m B: Polyurethane B: Polyurethane 3: Filters G4 + M6 (fresh air intake) Group 22: Miscellaneous item 1 A: Wheel speed with on/off control C: Inera® C: Inera® B: Wheel speed with variable control 000 Without options D: Copper D: Copper 1: Channel cross section of 2,0 mm 1: Management of an on/off humidifier E: Blygold® E: Blygold® 2: Channel cross section of 2,5 mm 2: Management of aproportional humidifier Group 8: Heating A: Material: Aluminium E: Energy meter 000: Without auxiliary heating B: Material: Aluminium with epoxy M: Energy meter and calculation of cooling • and heating capacities •G0x: Gas burner, 3 power outputs: C: Material: Hybrid wheel 1: Refrigerant leak detector x = Low (L) / Nominal (N) / High (H) D: Material: aluminium with silicagel •G1x: Boiler + hot water coil, 3 power outputs: Group 17: Extra heating Group 23: Miscellaneous item 2 Low (L) / Nominal (N) / High (H) 0: Without extra heating C100 Electrical switchgear + std phase relay E0x: Electrical heaters, 3 power outputs: • • N eater) in fresh air (N):Preheater (electrical h 1: Compressor soft starter Low (L) / Nominal (N) / High (H) • L: Preheater (electrical heater) in fresh air (L) T: Tropicalization B0x: Hot water coil , 2 options: • • C: Heat recovery coil 2: High performance phase monitoring relay x = Standard (S) / Great cold (C) • A: High performance switchgear Group 18: Special applications Group 9: Protection for low outdoor temperature 0: Without special applications Group 24: Centrifugal return fan • • 0: Without protection H: Active dehumidification condensation coil 0000 Without centrifugal return fan • •1 Kit 1: Kit for outdoor temperature <-10ºC: Z: Air zoning 1: Low flow + nominal pressure • •2Kit 2: Kit for outdoor temperature <-14ºC: I: Low return temperature application 2: Low flow + high pressure • •3Kit 3 : Kit 1 + Dampers with spring: K: Low T application + Air zoning 3: Nominal flow + nominal pressure • • 4: Kit 4 : Kit 2 + Dampers with spring M: Low T application + Active dehumidification 4: Nominal flow + high pressure • Group 10: Available pressure of the indoor fan • N: 100% fresh air 5: High flow + nominal pressure N: 3 available pressures • O: 100% fresh air + Air zoning 6: High flow + high pressure • Low (L) / Nominal (N) / High (H) Group 19: Sensors 7: Low flow + low pressure 0000 Without options 8: Nominal flow + low pressure Group 11: Air filtration + stop-drop 9: High flow + low pressure A: G4 H: Smoke detector sensor • A: Air quality sensor for environment Unused B: G4+ stop-drop • C: Air quality sensor duct-mounted C: G4 low pressure drop Group 25: Indoor air direction • D: Double quality sensor: environment + • D: G4 low pressure drop + stop-drop environment 0000 Lower direction • E: G4 + M6 E: Double quality sensor: environment + 0: Lower supply and lower return • F: G4 + M6 + stop-drop outdoor 1: Lateral supply and lower return • G: G4 + F7 F: Double quality sensor: duct-mounted + 2: Lower supply and lateral return • H: G4 + F7 + stop-drop outdoor 3: Lateral supply and lateral return • I: G4 + F9 P: Air quality sensor on the pLAN network Unused 234 234 CATALOGUE 2021