AQUACIATPOWER TM LD Water chillers teChniCalChaRaCteRistiCs AQUACIATPOWER TMLD HE 602 650 750 80010001100125013501500 1600 1750 2000 Cooling Standard unit Nominal capacity kW 168 180 197 216 261 300 331 365 397 430 464 523 Full load performances* CA1 EER kW/kW 3,043,12 2,982,97 2,90 2,97 2,922,952,90 2,942,90 2,90 Nominal capacity kW 216 247 263 297 336 393 428 475 510 556 593 676 CA2 EER kW/kW 3,6 3,893,59 3,7 3,37 3,53 3,4 3,473,37 3,453,343,38 Standard unit kWh/ 4,32 4,29 4,18 4,25 4,20 4,52 4,40 4,52 4,374,674,70 4,65 Seasonal energy efficiency** kWh % 170 169 164 167 165 178 173 178 172 184 185 183 kWh/ 5,435,61 5,325,565,165,605,245,625,325,505,385,26 kWh Unit + low temperature brine kWh/ solution option 3,033,403,383,333,223,403,063,473,42 NA NA NA Seasonal energy efficiency** kWh Part Load integrated values IPLV.SI kW/kW 4,7584,8554,7334,8494,7494,9994,8335,0044,8154,9254,9994,839 Sound levels Standard unit Sound power(1) dB(A) 91 92 92 92 92 93 93 93 93 94 94 94 Sound pressure at10 m(2) dB(A) 59 60 60 60 60 60 60 61 61 62 62 62 Unit + Low Noise option Sound power(1) dB(A) 89 90 90 90 90 91 91 92 92 93 93 93 Sound pressureat 10 m(2) dB(A) 57 58 58 58 58 59 59 60 60 60 60 60 Unit + Xtra Low Noise option Sound power(1) dB(A) 84 84 84 85 85 86 86 86 86 87 87 87 Sound pressure at10 m(2) dB(A) 52 52 52 53 53 54 54 54 54 55 54 54 Dimensions - Standard unit Length mm 2410 3604 4797 Width mm 2253 2253 2253 Height mm 2324 2324 2324 Unit + Buffer tank module option mm 3604 4798 5991 Operatingweight(3) Standard unit kg 1258130213021431 1453191219472116217426142631 2842 Unit + Low Noise option kg 1341 1385138515391561 2038207322602318277627933022 Unit + Low Noise option + HP dual-pump hydraulic module kg 15191563156317171754223423142501 2558305730743339 Unit + LowNoise option + HP dual-pump hydraulic module+ Buffer tank module kg 247825222522267627133193327334603517401640334298 Compressors Hermetic Scroll 48.3 r/s Circuit A 1 1 1 2 2 2 2 3 3 3 3 4 Circuit B 2 2 2 2 2 3 3 3 3 4 4 4 No. of power stages 3 3 3 4 4 5 5 6 6 7 7 8 * In accordance with standard EN14511-3:2013. ** In accordance with standard EN14825:2016, average climate conditions. *** With 30 % brine solution CA1 Conditions in cooling mode: Evaporator water inlet/outlet temperature 12 °C/7 °C, outdoor air temperature 35°C, evaporator fouling factor0 m. k/W.2 CA2 Cooling mode conditions: evaporator water inlet/outlet temperature 23 °C/18 °C, outdoor air temperature 35 °C, evaporator fouling factor0 m. k/W.2 Ƞs cool12/7°C & SEER 12/7°CValues in bold comply with Ecodesign Regulation (EU) No. 2016/2281 for Comfort application SEPR 12/7°C Values in bold comply with Ecodesign Regulation (EU) No. 2016/2281 for Process application SEPR -2/-8°C Values in bold comply with Ecodesign Regulation (EU) No. 2015/1095 for Process application NA Not authorised for the specific application for the EEC market. IPLV.SI Calculated as per AHRI standard 551-591 (SI). (1) indB ref=10-(12)W, 'A' weighted. Declared dual-number noise emission values in accordance with ISO 4871 with an associated uncertainty of +/-3dB(A). Measured in accordance with ISO 9614-1 and certified by Eurovent. (2) I n dB ref 20µPa, 'A' weighted. Declared dual-number noise emission values in accordance with ISO 4871 with an associated uncertainty of +/-3dB(A). For information, calculated from the sound power level Lw(A). (3) Values are guidelines only. Refer to the unit name plate. Eurovent certified values 426 426 CATALOGUE 2021