AQUACIATPOWER TM LD/ILD Water chiller & heat pump teChniCalChaRaCteRistiCs -ReveRsibleheatpUmp AQUACIATPOWER TMILD 1250R 1400R 1500R 1600R 1750R 2000R Heating Nominal capacity kW 336 387 406 441 467 537 HA1 Standard unit COP kW/kW 3,81 3,82 3,81 3,80 3,73 3,80 Full load performances* Nominal capacity kW 329 378 397 431 458 526 HA2 COP kW/kW 3,09 3,10 3,09 3,10 3,03 3,09 SCOP30/35°C kWh/kWh 3,58 3,55 3,57 3,54 3,53 3,57 Seasonal energy HA1 ηs heat 30/35°C % 140 139 140 139 138 140 efficiency** Prated kW 266 305 321 349 371 425 Unit + Rated & Seasonal high Nominal capacity kW 336 387 406 441 467 537 performance options HA1 Full load performances* COP kW/kW 3,81 3,82 3,81 3,80 3,73 3,80 SCOP30/35°C kWh/kWh 3,86 3,90 3,91 3,92 3,89 3,96 Seasonal energy HA1 ηs heat % 151 153 153 154 153 155 efficiency** 30/35°C Prated kW 265 305 320 348 370 424 Cooling Standard unit Nominal capacity kW 305 341 358 389 414 470 Full load performances* CA1 EER 2,59 2,64 2,57 2,64 2,55 2,55 Seasonal energy SEER 12/7°C Comfort low temp. kWh/kWh 4,50 4,46 4,33 4,44 4,38 4,32 efficiency** SEPR 12/7°C Process high temp. kWh/kWh 4,76 4,93 4,79 4,94 4,82 4,83 Unit + Rated & Seasonal high Nominal capacity kW 324 362 381 413 439 500 performance options CA1 Full load performances* EER kW/kW 2,80 2,82 2,76 2,81 2,74 2,73 Seasonal energy SEER 12/7°CComfort low temp. kWh/kWh 4,81 4,88 4,87 4,81 4,75 4,81 efficiency** SEPR 12/7°Cess high tempProc kWh/kWh 5,34 5,60 5,40 5,60 5,43 5,47 . Sound levels Unit + High temperature option/Nominal high performance Sound power(1) dB(A) 93,5 94,0 94,0 94,5 94,5 95,0 Sound pressureat 10 m (2) dB(A) 61,5 62,0 62,0 62,0 62,0 62,5 Standard unit Sound power(1) dB(A) 91,0 91,5 91,5 92,0 92,5 93,0 Sound pressure at10 m (2) dB(A) 58,5 59,5 59,5 60,0 60,0 60,5 Unit + Very Low Noise option(3) Sound power(1) dB(A) 88,0 89,0 89,0 89,5 90,0 90,0 Sound pressure at 10m (2) dB(A) 55,5 56,5 56,5 57,0 57,5 57,5 Unit + Ultra Low Noise option(3) Sound power(1) dB(A) 86,0 86,5 87,0 87,5 87,5 88,0 Sound pressureat 10 m (2) dB(A) 54,0 54,5 55,0 55,5 55,5 56,0 * In accordance with standard EN14511-3:2013. ** In accordance with EN14825:2013, average climate conditions HA1 Heating mode conditions: water type heat exchanger water inlet/outlet temperature 30 °C/35 °C, outdoor air temperature tdb/twb= 7 °C db/6 °C wb, evaporator fouling factor 0 m. k/W2 HA2 Heating mode conditions: water type heat exchanger water inlet/outlet temperature 40 °C/45 °C, outdoor air temperature tdb/twb = 7 °C db/6 °C wb, evaporator fouling factor 0 m2. k/W CA1 Cooling mode conditions: evaporator water inlet/outlet temperature 12 °C/7 °C, outdoor air temperature 35 °C, evaporator fouling factor0 m. k/W2 Ƞs heat 30/35°C & SCOP 30/35°C Values in bold comply with Ecodesign Regulation (EU) No. 813/2013 for Heating applications SEER 12/7 °C& SEPR 12/7 °CApplicable Ecodesign regulation (EU) No. 2016/2281 (1) IndB ref=10-12W, 'A' weighted. Declared dual-number noise emission values in accordance with ISO 4871 with an associated uncertainty of +/-3dB(A).Measured in accordance with ISO 9614-1 and certified by Eurovent. (2) In dB ref 20µPa, 'A' weighted. Declared dual-number noise emission values in accordance with ISO 4871 with an associated uncertainty of +/-3dB(A). For information, calculated from the sound power Lw(A). Eurovent certified values 402 402 CATALOGUE 2021