HYDROCIATTURBO TMLWT Water chillers Heat pump Options Options Description Advantages HYDROCIATTURBO TM LWT Master/slave Unit equipped with supplementary water outlet tempera- Optimised operation of two units connected in parrallel operation operation ture sensor kit (tobe field installed) allowing master/slavewith operating time equalisation ● operation of two units connected in parallel Single power Unit power connection via one main supply connection Quick and easy installation 2300/4200 connection point Evap. single pump Unit equipped with an electrical power and control circuit Quick and easy installation: the control of fixed speed pumps is 1400/3100 power/control circuit for one pump evaporator side embedded in the unit control Cond. single pump Unit equipped with an electrical power and control circuit Quick and easy installation: the control of fixed speed pumps is 1400/3100 power/control circuit for one pump condenser side embedded in the unit control Condenser insu- Thermal condenser insulation Minimizes thermal dispersions condenser side (key option for lation heat pump or heat recovery applications) ● Service valve set Liquid line valve (evaporator inlet) and compressor Allow isolation of various refrigerant circuit components for suction line valve simplified service and maintenance ● Evaporator with one Evaporator with one pass on the water side. Evaporator Easy to install, depending on site. Reduced pressure drops pass less inlet and outlet on opposite sides. ● Condenser with one Condenser with one pass on the water side. Condenser Easy to install, depending on site. Reduced pressure drops pass less inlet and outlet on opposite sides. ● Reversed evaporator water Evaporator with reversed water inlet/outlet Easy installation on sites with specific requirements ● connections Reversed condenser water Condenser with reversed water inlet/outlet Easy installation on sites with specific requirements ● connections Bacnet over IP Bi-directional high-speed communication using BACnet Easy and high-speed connection by ethernet line to a building man- protocol over Ethernet network (IP) agement system. Allows access to multiple unit parameters ● Simple installation: for applications with cold water at condenser Control for low Output signal (0-10 V) to control the condenser water inlet (ex. ground-source, groundwater-source, superficial wa- cond. temperature inlet valve ter-source applications) the signal permits to control a2 or 3-way ● valve to maintain condenser water temperature (and so condensing pressure) at acceptable values Control box for communication with the drycooler via a bus. Specific dry cooler For OPERA drycooler need to select the cabinet with op- Permits the use of an energy-efficient plug-and-play system control tion control cabinet manage by the chiller Connect'Touch ● control Input contact for 0-10 V signal to report any refrigerant leakage in the Immediate customer notification of refrigerant losses to the Refrigerant leak unit directly on the controlller (the leak detector itself atmosphere, allowing timely corrective actions ● detection must be supplied by the customer) Compliance with Additional tests on the water heat exchangers: supply Swiss regulations (additional of PED documents) supplementary certificates Conformance with Swiss regulations ● and test certifications Compliance with EAC certification Conformance with Russian regulations Russian regulations ● Flanged evaporator Victaulic piping connections with flanged joints Easy installation water connection kit ● Flanged condenser Victaulic piping connections with flanged joints Easy installation water connection kit ● 230Velectrical plug 230V AC power supply source provided with plug socket Permits connection of a laptop or an electrical device during unit and transformer (180 VA, 0,8 Amps) commissioning or servicing ● M2M supervision Monitoring solution which allows customers to track and Real-time expert technical support to improve equipment avail- (accessory) monitor their equipment remotely in real time ability and reports at customer hand to monitor and optimize ● operating equipment. Anti-vibration Elastomer antivibratils mounts to be place under the unit Isolate unit from the building, avoid transmission of vibration and mounts (kit) (Material classified B2 fire class according to DIN 4102 associate noise to the buiding. Must be associate with flexible ● ). connection on water side Exchangers Easy installation. Limit transmission of vibrations on the water flexibles connection Flexibles connections on the exchanger water side network ● (kit) Free Cooling dry Control & connections to a Free Cooling Drycooler Opera Easy system managment, Extended control capabilities to a dryc- cooler management or Vextra fitted with option FC control box coler used in Free Cooling mode ● Heat Pump ap- Unit configurated for Heat Pump application, include Optimisation on heating mode & minimize thermal dispersions plication thermal condenser insulation condenser side ● ● ALL MODELS Refer to the selection tool to find out which options are not compatible CATALOGUE 2021 563 563