AQUAIR BCP® Air handling units for swimming pools Technical characteristics AQUAIR®BCP 110 140 180 230 265 315 355 Dehumidification capacity 1 (kg/h) 21,7 27,3 36,1 44,6 53,4 65,5 74,4 Heating capacity (kW) 27,5 30,1 42,0 55,0 63,4 69,5 85,2 Cooling capacity 2 (kW) 31,6 39,7 53,3 67,3 77,1 95,2 108,2 Power input 3 (kW) 7,0 8,8 12,4 15,6 18,5 22,9 25,6 Air Nominal air flow rate (m3/h) 5 500 7 000 9 000 11 500 13 250 16 000 16 000 circuit Maximum air flow rate (m3/h) 6 600 8 400 10 800 13 800 15 900 19 200 19 200 Available static pressure 7 (mmWC) 15 15 15 15 15 15 15 Fan type/Quantity Centrifugal/1 Power (kW) 1,1 1,5 2,2 3,0 4,0 5,5 5,5 Nominal air flow rate (m3/h) 10 500 10 500 17 250 17 250 24 000 24 000 24 000 High-fl ow Available static pressure (mmWC) 15 15 15 15 15 15 15 air circuit (option) Fan type/Quantity Centrifugal/1 Power (kW) 3,0 3,0 5,5 5,5 7,5 7,5 7,5 Heating capacity 4 (kW) 10 16,9 20,7 24,9 28,2 43,1 43,1 Water Nominal water flow rate (m3/h) 1,73 2,92 3,57 4,30 4,86 7,45 7,45 condenser Pressure drop (mmWC) 4,4 3,2 4,7 3,9 5,0 4,6 4,6 Hydraulic connections 1" 1 1/4" 1 1/4" 1 1/2" 1 1/2” 1 1/2” 1 1/2” Heating capacity 5 (kW) 61,5 71,5 90,0 105,0 129,0 145,0 145,0 Auxiliary Nominal water flow rate (m3/h) 3,2 3,7 4,7 5,5 6,7 7,5 7,5 hot water coil (optional) Pressure drop (mmWC) 2,3 3,1 1,4 1,8 2,1 2,6 2,6 Hydraulic connections 1 1/4” 1 1/4" 1 1/2" 1 1/2" 1 1/2” 1 1/2” 1 1/2” Type Scroll No. of compressors /No. of stages 2 3 Compressor No. of air/recovery circuits 1 / 1 2 / 1 Oil volume (l) 1,7 / 1,0 3,3 / 1,4 3,3 / 1,7 4 / 1,7 6,2 / 1,7 3,3+1,7/3,3 3,3x2/ 3,3 Electrical power supply 3 Wires + Earth + Neutral Max. input 400 V / III ph / 50 Hz (A) 37,7 31,6 48,0 55,9 61,0 86,6 98,6 current Type R-407C Refrigerant Global warming 1 652,5 potential (GWP) 6 Charge (kg) 7,4 8,6 14,7 15,5 17,8 16,9 18,2 Length (mm) 2 070 2 070 2 282 2 282 2 450 2 450 2 450 Dimensions Width (mm) 1 248 1 248 1 498 1 498 1 498 1 498 1 498 Height ( mm) 1 315 1 315 1 613 1 613 1 813 1 813 1 813 Weight (kg) 630 665 895 920 1 080 1 155 1 175 Condensate drain diameter 3/4” tube 1Dehumidification capacity of refrigeration system. When selecting a unit, take into account the moisture removal capacity of the outdoor air provided by the fan (UNE 100011). 2 Cooling capacity for air inlet temperature conditions of 28°C and 65% RH. 3 Total input power of the compressor and fan motor assemblies under rated conditions. 4 Heating capacity for water in recovery circuit: 28/33ºC. 5 Boiler water for the auxiliary hot water coil 82/65ºC and air intake at 20ºC. 6 Global warming potential of one kilogram of a fluorinated greenhouse gas relative to one kilogram of carbon dioxide over a period of 100 years. 7 For greater operating pressures, please consult us CATALOGUE 2021 225 225