SC Air-cooled condensing units Unit components Options - Casing made of galvanised steel metal with polyester paint, ■ Outdoor environment grey graphite colour RAL 7024 and white RAL 7035. Self- Temperature supporting frame. - Electricalheater for protection of the components of the ■ Air circuit electric panel. This is compulsory if the outdoor temperature - Axial 2-speed fan(s) directly coupled to the motor (models is below -8 °C WB. For outdoor temperatures below -16 ºC 90 to 182 wired to high speed). Watertight motor class F, WB, a reinforced heater will be compulsory. IP54 and internal thermal protection. Dynamically balanced - Compressor with protection against low temperatures propellers and outdoor protective grille. (supplementary crankcase heater). This is compulsory if the - Coil(s) with copper pipes and aluminium fins. Two designs: outdoor temperature is below -8 °C WB. • Models 90 to 320: U coil • Models 360 to 600: V coils Corrosion - Condensates drain pan (on models 360 to 600). - Coil with copper pipes and copper fins. - I NERA coil® with copper pipes and fins made from an ■ Refrigerant circuit aluminium alloy, offering high performance and great - Hermetic scroll-type compressor(s) with sound insulation, resistance to corrosion. fitted on anti-vibration mounts. Control of phase balance and - Coil with copper pipes and aluminium fins with polyurethane the direction of rotation. and Blygold coating.® - Crankcase heater. Humidity - Thermostatic expansion valve(s) with external balancing - Tropicalised electrical panel. (heat pump units). - Tropicalised motors and fans (contact us). - Four-way cycle reversing valve(s) (heat pump units). - Particle separator(s), anti-acid dehydrating filter(s) ■ Installation and liquid tank(s). - Rubber anti-vibration mounts. - Cooling connections for welding. - Service valves and refrigerant load for refrigerant connections - Maximum equivalent length of the cooling line 50 metres (for (up to 7.5 metres long). longer distances, it is necessary to use an oil separator). - Oilseparator for refrigerant connections with maximum ■ Safety devices equivalent length of the cooling line over 50 metres. - Air coil protection grille (models 90 to 320). - High- and low-pressure pressostats. - Condensate drain pan (on models 90 to 320). - Compressor discharge temperature control. - Non-return valve built into the compressor. - Main door switch. ■ Electrical cabinet - Thermal-magnetic protection switches for the compressor(s) - Electrical power supply with neutral. and fan(s) motor power line. - Automatic switch in the control circuit. - Energy meter for monitoring the power consumption of the installation (with CIATrtc control). ■ Electrical cabinet • Models 90 to 182: available if the unit does not incorporate - Complete and fully wired electrical panel.Insulated panel electrical heaters. cover to prevent condensation. Protection IP55. • Models 200 to 600: available with all options. - Transformer for power supply without neutral included in the ■ Energy saving electrical panel. - Main ground connection. Electronic EC axial fans that adjust their rotation - Compressor(s) and fan(s) motor contacts. speed to the installation requirements, thereby reducing electricity consumption, the sound level at partial charge and improving the average seasonal output of the unit. U, V coil Coils in V 280 280 CATALOGUE 2021