AQUACIATPOWER TM LD Water chillers availableoptions Options Description Advantages LD ST / HE 602-2000 Single low-pressure water pump, water filter, electronic LP single-pump hydraulic water flow control, pressure transducers. For more module details,refer to the dedicated chapter (expansion Easy and fast installation (plug & play) 602 to 1500 tank not included; option with built-in hydraulic safety components available) Dual low-pressure water pump, water filter, electronic LP dual-pump hydraulic water flow control, pressure transducers. For more module details,refer to the dedicated chapter (expansion Easy and fast installation (plug & play) 602 to 1500 tank not included; option with built-in hydraulic safety components available) Single high-pressure water pump with variable speed drive (VSD), water filter, electronic water flow control, pressure Quick and easy installation (plug & play), significant HP evap. variable-speed transducers. Multiple water flow control options. For more pumping energy cost savings (more than two-thirds), single-pump details, refer to the dedicated chapter (expansion tank not ● included; option with built-in hydraulic safety componentstighter water flow control, improved system reliability available) Dual high-pressure water pump with variable speed drive (VSD), pressure transducers. Multiple water flowQuick and easy installation (plug & play), significant HP variable-speed dual pump.control options. For more details, refer to the dedicatedpumping energy cost savings (more than two-thirds), ● chapter (expansion tank not included; option withtighter water flow control, improved system reliability built-in hydraulic safety components available) Lon gateway Bi-directional communication board complying withConnects the unit by communication bus to a building Lon Talk protocol management system ● Bi-directional high-speed communication using Easy and high-speed connection by ethernet line to a BACnet/IP BACnet protocol over Ethernet network (IP) building management system. Allows access to multiple ● unit parameters Contro board wit additional inputs/outputs.l h Extended remote control capabilities (setpoint reset by Energy Management Module See Contacts available in option on control description.0-20 mA input, ice storage end, demand limits, boiler ● on/off command...) Contact for refrigerant leak0-10 V signal to report any refrigerant leakage directlyImmediate customer notification of refrigerant losses to detection on the unit (the leak detector must be supplied by thethe atmosphere, allowing timely corrective actions ● customer) Dual relief valves on 3-way Three-way valve upstream of relief valves on the shell Valve replacement and inspection facilitated valve and tube evaporator without refrigerant loss. Conforms to European standard602 to 1000 EN378/BGVD4 Compliance with Russian EAC certification Compliance with Russian regulations regulations ● Power factor correction Capacitors for automatic regulation of power factorReduction of the apparent electrical power, compliance (cos phi) value to 0,95. with minimum power factor limit set by utilities ● Coating by conversion process which modifies the MCHEanti-corosion protecti surface of thealuminium producing a coating that isProtect2 Improved corrosion resistance of the on integral to the coil. Complete immersion in a bath toMCHE coils by 2, recommended for use in moderately Protect2 ● ensure 100% coverage. No heat transfer variation,corrosive environments tested 4000 hours salt spray per ASTM B117 Flexible, durable polyepoxide coating applied using an electro coating process to give micro-channel coilsProtect4 Improved corrosion resistance of the MCHE anti-corosion protectionan anti-UV top layer. Minimal variation in the thermalMCHE coils by 4, recommended for use in corrosive Protect4 transfer, tested to withstand more than 6000 hours ● of constant neutral salt spray as per ASTM B117, environments improved impact resistance as per ASTM D2794 Shell and tubes heat Brazed plate heat exchanger replaced by shell & tubeExtended water flow range, reinforced fouling 602 to 1000 exchanger heat exchanger resistance 230Velecrical plugt 230V AC power supply source provided with plug Permits connection of a laptop or an electrical device socket and transformer (180 VA, 0.8 Amps) during unit commissioning or servicing ● Expansion vessel 6 bar expansion tank integrated in the hydraulic module Easy and fast installation (plug & play), & protection ofALL units with pump (requires hydraulic module option) closed water systems from excessive pressure option Screwed water connection DSH connections with screw connection sleeves Easy installation. Used to connect the unit to a screw seeve kit for DSHl connector ● ● ALL MODELS Refer to the selection tool to find out which options are not compatible. 422 422 CATALOGUE 2021