JUNIORTM BCP Air a handling units for swimming pools Technical characteristics JUNIORTMBCP 20 30 40 50 60 70 80 90 Dehumidification capacity 1 (kg/h) 3,9 5,1 7,1 8,7 10,7 12,6 14,3 15,2 Heating capacity (kW) 7,2 9,4 13 16 19,8 11,3 12,8 13,9 Cooling capacity 2 (kW) 5,6 7,3 10,2 12,6 15,5 18,2 20,7 22 Power input (kW) 2 2,5 3,4 4 4,9 6 6,7 7,3 Air Nominal air flow rate (m3/h) 1 200 1 500 2 100 2 600 3 200 3 700 4 300 4 600 circuit Maximum air flow rate(m3/h) 1 440 1 800 2 520 3 120 3 840 4 440 5 160 5 520 Available static pressure (mmWC) 15 15 15 15 15 17 15 13 Fan type/Quantity Centrifugal/1 Power (kW) 0,4 0,4 0,6 0,6 0,6 1,1 1,1 1,1 Availability Non Option Standard Heating capacity 3 (kW) -- -- 6,6 8,2 10,1 11,8 13,5 14,3 Water Nominal water flow rate (m3/h) 1,2 1,4 1,8 2,1 2,4 2,7 condenser -- -- Pressure drop (mmWC) -- -- 1 1,3 1,9 1,1 1,4 1,7 Hydraulic connections -- -- 1” 1” 1” 1 1/4” 1 1/4” 1 1/4” Availability Option Auxiliary Heating capacity 4 (kW) 15,4 16,5 18,5 21 23,6 35 39,7 41,1 hot water Nominal water flow rate (m3/h) 0,8 0,9 1 1,1 1,2 1,8 2,1 2,1 coil (optional) Pressure drop (mmWC) 1,7 2,4 0,6 0,7 0,9 1,6 1,9 2 Hydraulic connections 3/4” 3/4” 1” 1” 1” 1 1/4” 1 1/4” 1 1/4” Type Scroll Compressor Number/Number of circuits 1 / 1 Oil volume (l) 1 1 1,1 1,4 1,7 1,7 1,7 3,3 Electrical 230 V / I ph / 50 Hz 2 wires + earth -- power supply 400 V / III ph / 50 Hz 3 wires + earth + neutral -- Max. input 230 V / I ph / 50 Hz (±10%) (A) 17,1 21,6 30,6 -- -- -- -- -- current 400 V / III ph / 50 Hz (±10%) (A) 15,6 17,6 20,6 18,6 21,6 21,6 -- -- Type R407C Refrigerant Global warming 1,744 potential (GWP) 5 Charge (kg) 2,3 2,2 2,8 3,4 3 4,8 4,9 5,7 Length (mm) 1 430 1 430 1 530 1 530 1 530 1 082 1 082 1 082 Dimensions Width (mm) 658 658 838 838 838 680 680 680 Height (mm) 636 636 700 700 700 2 143 2 143 2 143 Poids (kg) 168 172 208 212 222 300 302 329 Evacuation des condensats Ø 3/4” connection 1Dehumidification capacity of the refrigeration unit. When selecting the unit, the dehumidification required by the provision of outdoor air for ventilation purposes (UNE 100011) must be taken into account. 2 Cooling capacity for air intake temperature conditions of 28°C and 65% RH 3 Heating capacity for water in the recovery circuit: 28/33°C Recovery of 50% of the condensation capacity. 4 Boiler water for the auxiliary hot water coil 82/65ºC and air intake at 20ºC. 5 Global warming potential of one kilogram of a fluorinated greenhouse gas relative to one kilogram of carbon dioxide over a period of 100 years. Technical characteristics of the self-contained return module (option) JUNIORTMBCP 20 30 40 50 60 70 80 90 Return Avail. static pressure (mmWC) 11 10 11 10 10 10 10 10 air fan Fan type/Quantity Centrifugal/1 (option) Fan power (kW) 0,1 0,1 0,5 0,5 0,5 0,5 0,6 0,6 Length (mm) 1 417 1 417 1 500 1 500 1 500 1 500 1 500 1 500 Dimensions Width (mm) 660 660 840 840 840 840 840 840 Height ( mm) 636 636 700 700 700 700 700 700 Weight (kg) 90 90 139 139 139 139 140 140 214 214 CATALOGUE 2021