VECTIOSPOWER TM PJ Compact air-air rooftop units Model number nomenclature IPJ_0420 A 3 U C0 AA 000 0 N B E 0 00000000000 0 0 T100 00 P00 000C10000000000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24 25 Group 1: Unit type Group 12: Type of outdoor fan Group 21: Terminal + Unit communication • IPJ: air/air heat pump • A: AC (2-speed) 000 Without terminal + stand-alone + without card Group 2: Unit model • E: EC (electronic) M: Communication card RS485 Modbus/ Group 13: Insulation Carel •2 circuits: 0420 / 0450 / 0500 E: Communication card Ethernet PCoWeb 0560 / 0620 / 0680 / 0720 • 0: Standard insulation L: Communication card RS485 LonWorks® Insulation M0 with double wall (50mm) 0760 / 0840 / 0960 • 1: B: Communication card Ethernet BACnetTM 1050 / 1200 Group 14: Indoor unit configuration C: Communication card RS485 BACnetTM Group 3: Version of the series 000 Without optional accessories K: Communication card RS485 Konnex A: Condensate drain pan in stainless steel 0: Free-standing unit Group 4: Electrical power 1: Unused 1: Master unit • 3: 400V / 3ph + N / 50Hz A: Clogged filters pressostat 2: Slave unit • 4: 400V / 3ph / 50Hz Group 15: Outdoor unit configuration P: VecticGD terminal in electrical cabinet Group 5: Type of refrigerant T: TCO user terminal in electrical cabinet 0000 Without optional accessories R: VecticGD terminal in electrical cabinet + • U: R410A A: Fresh air intake protection grid TCO terminal remote up to 100 m Group 6: Air flow + Assembly 1: Outdoor coil protective grille S: TCO terminal in electrical cabinet + A: Antivibration mounts VecticGD terminal remote up to 200 m •C0: Standard assembly 1: Stop-drop at the fresh air intake N: VecticGD terminal in electrical cabinet + •CS: 2 dampers VecticGD terminal remote up to 200 m CP: Lower return plug-fan Group 16: Passive recovery • CR: Lower return plug-fan and active recovery 0000 Without optional accessories Group 22: Miscellaneous item 1 • CQ: Return plug-fan or centrifugal fan in top box 4: Wheel diameter: 1500 mm 000 Without optional accessories • CT: Return plug-fan or centrifugal fan in top box 5: Wheel diameter: 1800 mm 1: Management of an on/off humidifier • and active recovery 6: Wheel diameter: 2000 mm 2: Management of aproportional humidifier CW: Passive recovery 7: Wheel diameter: 2200 mm E: Energy meter • A: Wheel speed with on/off control M: Energy meter and calculation of cooling Group 7: Coil coating : Indoor - Outdoor B: Wheel speed with variable control and heating capacities •AA: Aluminium - Aluminium 1: Channel cross section of 2,0 mm 1: Refrigerant leak detector •AB: Aluminium - Polyurethane 2: Channel cross section of 2,5 mm AC: Aluminium Inera® A: Material: Aluminium Group 23: Miscellaneous item 2 • - BB: Polyurethane - Polyurethane C: Material: Hybrid wheel C100 Without optional accessories • BC: Polyurethane - Inera® Unused • Group 17: Extra heating T: Tropicalization •CC: Inera® - Inera® 0: Without extra heating • Unused Group 8: Heating • C: Heat recovery coil Unused •000: Without auxiliary heating Group 18: Special applications Group 24: Return fan •G0x: Gas burner, 2 power outputs: 0: Without special applications x = Nominal (N) / High (H) • 0000 Without return fan • Z: Air zoning 1: Centrifugal, low flow •E0x: Electrical heaters, 3 power outputs: I: Low return temperature application • 3: Centrifugal, nominal flow x = Low (L) / Nominal (N) / High (H) K: Low T application + Air zoning • 5: Centrifugal,high flow •B0x: Hot water coil: N: Plug-fan, nominal pressure (Polypropyl.) x = Standard (S) Group 19: Sensors A: Plug-fan, nominal pressure (Aluminium) 0000 Without optional accessories Group 9: Protection for low outdoor temperature H: Smoke detector sensor H: Plug-fan, high pressure (Aluminium) • 0: Without protection A: Air quality sensor for environment Unused • 1: Kit 1: Kit for outdoor temperature <-10ºC C: Air quality sensor for return (duct-mounted) Group 25: Indoor airflow direction Group 10: Available pressure of the indoor fan D: Double quality sensor: ambient + ambient0000 Lower direction L: Low available pressure (Aluminium) E: Double quality sensor: ambient + outdoor 0: Lower supply and lower return • N: Nominal available pressure (Polypropylene) F: Double quality sensor: return + outdoor (C0, CS, CP, CR and CW assemblies) • P: Air quality sensor on the pLAN network • A: Nominal available pressure (Aluminium) 1: 1 sensor RS485 1: Lateral supply and lower return H: High available pressure (Aluminium) (C0, CS, CP, CR and CW assemblies) • 2: 2 sensors RS485 2: Lower supply and lateral return Group 11: Air filtration + stop-drop 3: 3 sensors RS485 (C0, CS, CQ and CT assemblies) • A: G4 4: 4 sensors RS485 3: Lateral supply and lateral return • B: G4 + stop-drop 5: 1 sensor NTC (C0, CS, CQ and CT assemblies) C: G4 low pressure drop T: Ambient temperature sensor 4: Upper supply and lower return • D: G4 low pressure drop + stop-drop H: Ambient temperature+humidity sensor (C0 and CS assemblies) • G: G4 + F7 P: Ambient sensor on the pLAN network 5: Lateral supply and upper return • (C0 and CS assemblies) H: G4 + F7 + stop-drop • Group 20: Free-cooling + Outdoor humidity 6: Upper supply and lateral return • K: G4 low pressure drop + F7 00 Without free-cooling + without sensor (C0 and CS assemblies) • L: G4 low pressure drop + F7 + stop-drop 1: Outdoor humidity sensor on the unit 7: Lower supply and upper return • O: M6 + F7 2: Outdoor humidity sensor on pLAN network (C0 and CS assemblies) • P: M6 + F7 + stop-drop T: Thermal free-cooling 8: Upper supply and upper return • S: F7 + F9 M: Thermoenthalpic free-cooling (C0 and CS assemblies) • T: F7 + F9 + stop-drop E: Enthalpic free-cooling Unused CATALOGUE 2021 255 255