EREBATM He Reversible air-to-water heat pump physiCaldata EREBATMHe 5H 7H 11H 15H 11 HT 15 HT Heating Nominal capacity kW 5,10 7,15 11,25 15,10 11,20 15,00 HA1 COP kW/kW 4,40 4,10 4,70 4,25 4,60 4,35 Standard unit Nominal capacity kW 4,85 6,80 11,30 13,40 10,40 13,50 Full load performances* HA2 COP kW/kW 3,40 3,20 3,60 3,40 3,60 3,50 Nominal capacity kW 4,45 6,75 11,20 11,65 10,25 11,80 HA3 COP kW/kW 2,80 2,70 2,95 2,90 3,00 3,00 SCOP30/35 °C kWh/kWh 4,73 4,68 4,39 4,41 4,26 4,35 HA1 Ƞ s heat 30/35 °C % 186 184 173 173 167 171 Standard unit SCOP47/55 °c kWh/kWh 3,32 3,36 3,35 3,45 3,34 3,40 Seasonal energy efficiency ** Ƞs heat47/55 °c % 130 131 131 135 131 133 HA3 Prated kW 3.49 4.32 8.69 10.30 8.69 11.09 Energy labelling A++ A++ A++ A++ A++ A++ Cooling Nominal capacity kW 4,00 5,55 11,20 12,80 10,65 13,00 CA1 EER kW/kW 3,10 3,10 3,40 3,10 3,40 3,20 Standard unit Eurovent class A A A A A A Full load performances (*) Nominal capacity kW 4,85 8,00 13,70 16,00 13,75 17,00 CA2 EER kW/kW 4,35 4,00 4,60 4,10 4,65 4,15 Eurovent class A A A A A A Standard unit SEER 12/7°C Comfort low temp. kWh/kWh 4,85 5,75 5,15 5,00 5,40 5,25 Seasonal energy efficiency ** Ƞs cool 12/7 °C % 191 227 203 197 212 208 Sound levels Standard unit Sound power level (2) dB(A) 64 65 68 69 69 69 Sound pressure level at 10 (3)m dB(A) 33 34 37 38 38 38 Dimensions Length mm 908 908 908 908 908 908 Width mm 350 350 350 350 350 350 Height mm 821 821 1363 1363 1363 1363 Operating weight(1) Standard unit kg 57 69 115 115 121 121 Compressors Rotary compressor 1 1 1 1 1 1 Refrigerant R410A Charge(1) kg 1,10 1,60 2,80 2,80 3 3 Capacity control Minimum capacity(4) % 23 % 20 % 20 % 17 % 20 % 17 % Condenser Grooved copper tubes, aluminium fins Fans Axial type * In accordance with standard EN14511-3:2013. ** In accordance with standard EN14825:2016, average climate HA1 Heating mode conditions: Water heat exchanger water entering/leaving temperature 30°C/35°C, outside air temperature tdb/twb = 7°C db/6°C wb, evaporator fouling factor0 m. k/W2 HA2 Heating mode conditions: Water heat exchanger water entering/leaving temperature 40°C/45°C, outside air temperature tdb/twb = 7°C db/6°C wb, evaporator fouling factor0 m. k/W2 HA3 Heating mode conditions: Water heat exchanger water entering/leaving temperature 47°C/55°C, outside air temperature tdb/twb = 7°C db/6°C wb, evaporator fouling factor0 m. k/W2 CA1 Cooling mode conditions: evaporator water inlet/outlet temperature 12 °C/7 °C, outdoor air temperature 35 °C, evaporator fouling factor 0 m2. k/W CA2 Cooling mode conditions: evaporator water inlet/outlet temperature 23 °C/18 °C, outdoor air temperature 35 °C, evaporator fouling factor 0 m2. k/W Ƞs heat30/35 °c& SCOP30/35 °CValues calculated in accordance with standard EN14825:2016 Ƞs heat& SCOP47/55°c 47/55 °CValues in bold comply with Ecodesign Regulation EU) No. 813/2013 for heating application( Ƞs cool12/7 °C& SEER 12/7 °C Values calculated in accordance with standard EN14825:2016 (1) Values are guidelines only. Refer to the unit nameplate (2) I n dB re.f=10-12 W, (A) weighting. Declared dual number noise emission value in accordance with ISO 4871 (with an associated uncertainty of +/-2dB(A)). Measured in accordance with ISO 9614-1 and certified by EUROVENT (3) I n dB ref 20 μPa, (A) weighting. Declared dual number noise emission value in accordance with ISO 4871 (with an associated uncertainty of +/-2dB(A)). For information, calculated from the sound power level Lw(A) (4) Cooling Eurovent condition Eurovent certified values 316 316 CATALOGUE 2021