AQUACIATCALEO TM TD Heat pump teChniCalChaRaCteRistiCs AQUACIATCALEO TMTD 70 80 100 120 150 200 300 Heating Standard unit Nominal capacity kW 20,6 25,9 32,3 43,4 51,5 64,7 102,0 Full load performances* HA1 COP kW/kW 4,11 4,02 4,04 4,27 4,32 3,97 4,24 Nominal capacity kW 20,6 25,5 32,0 43,0 51,6 66,6 102,0 HA2 COP kW/kW 3,46 3,37 3,35 3,56 3,64 3,42 3,58 Nominal capacity kW 20,7 25,0 31,6 42,7 52,2 67,9 102,0 HA3 COP kW/kW 2,99 2,91 2,89 3,10 3,16 3,00 3,12 Nominal capacity kW 21,0 24,6 31,3 42,6 53,3 68,0 103,0 HA4 COP kW/kW 2,50 2,43 2,42 2,60 2,66 2,52 2,64 Standard unit SCOP30/35°C kW/kW 3,45 3,44 3,53 3,51 3,62 3,47 3,51 Seasonal energy efficiency** HA1 ηs heat 30/35°C % 135 134 138 138 142 136 137 Prated kW 14,8 19,2 32,8 44,5 55,9 74,1 108,7 SCOP47/55°C kW/kW 2,92 2,94 2,97 3,00 3,08 2,99 3,15 HA3 ηs heat 47/55°C % 114 115 116 117 120 117 123 Prated kW 15 19 31 43 54 63 94 Energy labelling A+ A+ A+ A+ A+ A+ - Operating weight(1) Unit + hydraulic module option kg 362 418 435 555 579 919 1039 Sound levels Standard unit Soundpower (2) dB(A) 77 78 83 82 84 84 85 Sound pressureat 10m (3) dB(A) 46 46 51 51 53 52 53 Unit + Low Noise option Sound power(2) dB(A) 75 76 80 80 80 82 82 Sound pressureat 10m (3) dB(A) 44 44 49 48 49 50 51 Unit + Xtra Low Noise option Sound power(2) dB(A) NA NA 76 76 77 79 79 Sound pressureat 10m (3) dB(A) NA NA 45 45 45 47 47 Dimensions Length mm 1110 1114 2273 Depth mm 1327 2100 2100 Height mm 1440 1440 1440 Compressor Hermetic Scroll 48.3 r/s Quantity 1 1 1 1 1 2 2 Number of power stages 1 1 1 1 1 2 2 * In accordance with standard EN14511-3:2018. * In accordance with standard EN14825 2018, average climate.: HA1 Heating mode conditions: Waterheatexchanger water entering/leaving temperature 30°C/35°C, outside air temperature tdb/twb = 7°C db/6°C wb, evaporator fouling factor 0 m2. k/W HA2 Heating mode conditions: Water heat exchanger water entering/leaving temperature 40°C/45°C, outside air temperature tdb/twb = 7°C db/6°C wb, evaporator fouling factor 0 m2. k/W HA3 Heating mode conditions: Water heat exchanger water entering/leaving temperature 47°C/55°C, outside air temperature tdb/twb = 7°C db/6°C wb, evaporator fouling factor 0 m2. k/W HA4 Heating mode conditions: Water heat exchanger water entering/leaving temperature 55°C/65°C, outside air temperature tdb/twb = 7°C db/6°C wb, evaporator fouling factor 0 m2. k/W ηs heat 30/35°C& SCOP 30/35°C Values calculated in accordance with EN 14825:2018 ηs heat 47/55°C & SCOP47/55°C Values inbold comply with Ecodesign Regulation (EU) No. 813/2018 for heating application - Not applicable (1) Weight given as a guide. Please refer to the unit nameplate. (2) In dB ref=10-12 W, ‘A’ weighted. Declared dual-number noise emission values in accordance with ISO 4871 with an associated uncertainty of +/-2dB(A). Measured in accordance with ISO 9614-1 and certified by Eurovent. (3) In dB ref 20 µPa, ‘A’ weighted. Declared dual-number noise emission values in accordance with ISO 4871 with an associated uncertainty of +/-2dB(A). For information, calculated from the sound power Lw(A). Eurovent certified values 376 376 CATALOGUE 2021