VECTIOS™ PJ Compact air-air rooftop units Factory options and accessories Family Group Description Models Installation Installation in factory on site Electrical power 4 400 V / 3 ph / 50 (without neutral) All 4 Air flow + 6 CS: Cross flow with 2 dampers All 4 Assembly CK: Cross flow with 3 dampers All 4 CF: Cross flow 100% fresh air All 4 CA: Cross flow with axial return fan All 4 CP: Cross flow with lower return plug-fan All 4 CR: Cross flow with lower return plug-fan and cooling recovery circuit (active recovery) All 4 CQ: Cross flow with upper return plug-fan or centrifugal fan All 4 CT: Cross flow with upper return g-aor centrifugal fan and cooling recovery circuit (active recovery) All 4 CW: Cross flow with rotary heat exchanger (passive recovery) All 4 TS: Tunnel flow with 2 dampers 0200 to 0380 4 TP: Tunnel flow with return plug-fan 0200 to 0380 4 TW: Tunnel flow with rotary heat exchanger (passive recovery) 0200 to 0380 4 Coil coating 7 Coil with copper pipes and copper fins All 4 Coil with copper pipes and fins of an aluminium alloy (INERA®) All 4 Coil with copper pipes and aluminium fins with polyurethane coating All 4 Blygold® coating All 4 Heating 8 Auxiliary hot water coil : Standard or Great cold All 4 Auxiliary electrical heaters All 4 Natural or propane gas burner (supplied installed into a pre-assembly roofcurb) All 4 Gas boiler + Auxiliary hot water coil All 4 (*) Protection low 9 Kit 1: Antifreeze protection kit for low temperature (<-10ºC) All 4 temperature Kit 2: Antifreeze protection kit for low temperature (<-14ºC) All 4 Kit 3: Kit 1 + Dampers with spring All 4 Kit 4: Kit 2 + Dampers with spring All 4 Indoor fan 10 Indoor plug-fan with high available pressure or low available pressure All 4 Air filtration + 11 Stop-drop in the indoor air coil All 4 4 stop-drop Gravimetric filters G4 with low pressure drop All 4 4 Gravimetric filters G4 + folded opacimetric filters M6, F7 or F9 All 4 4 Gravimetric filters G4 low pressure drop + folded opacimetric filters F7 or F9 All 4 4 Double stage of folded opacimetric filters (M6+F7, M6+F9, F7+F9 or F9+F9) All 4 4 Outdoor fan 12 Axial 2-speed outdoor fan(s) directly coupled to the motor All 4 Insulation 13 Ceramic fibre for thermal and acoustic insulation, Euroclass A2-s1, d0 (M0) All 4 Indoor unit 14 Condensate drain pan in stainless steel All 4 4 Management of the overpressure All 4 Differential pressure switch to detect clogged filters All 4 Outdoor unit 15 Fresh air intake protection grid All 4 4 Outdoor coil protective grille All 4 4 Stop-drop at the fresh air intake All 4 4 Antivibration mounts made of rubber All 4 4 Passive recov. 16 Rotary heat exchanger with CW and TW assemblies All 4 Extra heating 17 Heat recovery coil All 4 Preheater (electrical heater) in fresh air, low or nominal power All 4 Special 18 Active dehumidification with condensation coil All 4 applications Air zoning All 4 Low return temperature application All 4 Low return temperature application + Air zoning All 4 Low return temperature application + Active dehumidification All 4 100% fresh air (without or with air zoning) All 4 Sensors 19 Ambient temperature sensor: one NTC sensor connected to the control board or 1 to 4 RS485 sensors All 4 4 Ambient temperatute + humidity sensor: one to four sensors with RS485 communication All 4 4 (Air quality sensor environment installed, duct-mounted, on a pLAN local network or double sensorenvironment + environment; environment + outdoor; duct-mounted + outdoor) All 4 4 Smoke detecting station in accordance with the NF S 61-961 standard All 4 4 Free-cooling + 20 Type of free-cooling: thermal, enthalpic or thermoenthalpic All 4 4 Outd. humidity Outdoor air humidity sensor: supplied with the unit or installed on a pLAN local network All 4 4 Terminal + Unit 21 TCO terminal installed in the electrical cabinet All 4 4 communication VecticGD terminal installed in the electrical cabinet + TCO terminal remote up to 100m All 4 4 TCO terminal installed in the electrical cabinet + VecticGD terminal remote up to 200m All 4 4 VecticGD terminal installed in the electrical cabinet + VecticGD terminal remote up to 200m All 4 4 Unit configuration: stand-alone, master or slave All 4 4 Communication cards: RS485 Modbus/Carel; Ethernet PCoWeb; RS485 LonWorks®; Ethernet BACnet ;TM 4 4 RS485 BACnet ; RS485 KonnexTM All Miscellaneous 22 Management of an humidifier with proportional or on/off control All 4 item 1 Energy meter All 4 Energy meter and calculation of the cooling and heating capacities All 4 Refrigerant leak detector All 4 Miscellaneous 23 Compressor soft starter All 4 item 2 Tropicalised components on the electrical cabinet: control board, cards and terminals All 4 High performance phase monitoring relay All 4 High performance magnetothermic switches All 4 Return fan 24 Centrifugal return fan (CQ and CT assemblies). 9 combinations of air flow and available pressure All 4 Air direction 25 0: Lower supply and lower return; 1: Lateral supply and lower return All 4 2: Lower supply and lateral return; 3: Lateral supply and lateral return Roofcurb -- Standardised pre-assembly roofcurbs with adjustable height Cross flow 4 Adaptation roofcurbs for replacing units on site Tunnel flow 4 (*) Part of this option must be intalled on-site. CATALOGUE 2021 237 237