VECTIOS™ PJ Compact air-air rooftop units Electrical power (Group 4) Note: the active dehumidification is not compatible with the These units can be supplied for the following power supply gas boiler. voltages: n400 V / 3 ph + N / 50 Hz (standard) n400 V / 3 ph / 50 Hz (optional) Coils coating (Group 7) nCoils with copper pipes and copper fins. Upon request. nCoils with copper pipes and fins of an aluminium alloy (INERA®), of high performance and great resistance to the corrosion. nCoils with copper pipes and aluminium fins with polyurethane coating. nBlygold® coating. Note: These coating can be applied to various coils (outdoor, indoor and hot water coil) according to the combinations nNatural or propane gas burner with modulating actuator, in available in our “Selection Software”. accordance with the Gas Directive 2009/142/EC, installed inside a pre-assembly roofcurb. Heating (Group 8) The PJ unit with lower air supply will be placed on this roofcurb. The unit only can incorporate one of these heating elements: Up to 3 values of total power available for each model: nAuxiliary electrical heaters, with two power stages and on/ off control, for assembly and connection inside the unit. VECTIOS™ PJ G0L (Low) G0N (Nominal) G0H (High) Up to 3 values of total power available for each model: 0090 to 0190 PCH020 PCH034 PCH045 VECTIOS™ PJ E0L (Low) E0N (Nominal) E0H (High) 0200 to 0240 unavailable PCH065 PCH080 0090 to 0120 12 kW 18 kW unavailable 0280 to 0380 unavailable PCH080 PCH105 0140 to 0190 12 kW 18 kW 27 kW Note: It’s recommended to use the clogged filter pressostat 0200 to 0380 18 kW 27 kW 36 kW (optional)in units with gas burner. nAuxiliary hot water coil,with three-way valve and proportional control, for assembly inside the unit. The unit incorporates an anti-freeze thermostat as safety system. There are two configuration types available: •Standard (B0S), the only safety system is the anti-freeze thermostat. •Great Cold (B0C), with anti-freeze technology based on the water temperature. This protection is made up of a circulation pump and two sensors inserted in the input and the output of the coil. Important: this option is mandatory for an outdoor temperature lower than -20ºC WB. Consult for percentages of glycol water above 20%. Note: on units with the “Great Cold” option, air supply only may be lateral (factory-configured). Note: the active dehumidification is not compatible with the hot water coil. nGas boiler + Auxiliary hot water coil. Natural or propane Pre-assembly gas boiler with modulating actuator, in accordance with the Gas burner roofcurb Gas Directive 2009/142/EC, mounted on the side of the unit. The boiler is connected to the water circuit of the auxiliary coil. Protection for low outdoor T (Group 9) Up to 3 values of total power available for each model: nKit 1: Antifreeze protective kit (<-10ºC). Mandatory for an G1L (Low) G1N (Nominal) G1H (High) outdoor temperature lower than -10ºC WB. VECTIOS™ PJ This kit includes: 0090 to 0190 unavailable Condexa PRO 40 Condexa PRO 70 (coming soon) •Electrical heater for protection of the components of the Condexa PRO 50 electrical cabinet. 0200 to 0380 (comin soon)g Condexa PRO 70Condexa PRO 100 •Compressor with protection for low temperature. 240 240 CATALOGUE 2021