VECTIOSPOWER TM PJ Compact air-air rooftop units Factory options and accessories Family GroupDescription Upon Installation Installation request in factory on site Electrical power 4 400 V / 3 ph / 50 (without neutral) 4 Air flow + 6 CS: 2 dampers mixing box 4 Assembly CP: Lower return plug-fan 4 CR: Lower return plug-fan and cooling recovery circuit (active recovery) 4 CQ: Return plug-fan or centrifugal fan in top box 4 CT: Return plug-fan or centrifugal fan in top box and cooling recovery circuit (active recovery) 4 CW: Lower return plug-fan and rotary heat exchanger (passive recovery) 4 (*) CK: 3 dampers mixing box 4 4 CL: Return plug-fan or centrifugal fan in top box and rotary heat exchanger (passive recovery) 4 4 (*) Coil coating 7 Coil with copper pipes and fins of an aluminium alloy (INERA®) 4 Coil with copper pipes and aluminium fins with polyurethane coating 4 Coil with copper pipes and copper fins 4 4 Blygold® coating 4 4 Heating 8 Auxiliary hot water coil Standard 4 Great cold 4 4 Auxiliary electrical heaters On-off control 4 Proportional control 4 4 Natural or propane gas burner (supplied installed into a pre-assembly roofcurb) 4 Protection low 9 Kit 1: Antifreeze protection kit for low temperature (<-10ºC) 4 temperature Kit 2: Antifreeze protection kit for low temperature (<-14ºC) 4 4 Kit 3: Kit 1 + Dampers with spring 4 4 Kit 4: Kit 2 + Dampers with spring 4 4 Indoor fan 10 Indoor plug-fan with nominal available pressure (Aluminum), low pressure (Aluminium) or high pressure (Aluminium) 4 Air filtration + 11 Stop-drop in the indoor air coil 4 4 stop-drop Gravimetric filters G4 with low pressure drop 4 4 Gravimetric filters G4 + folded opacimetric filters F7 4 4 Gravimetric filters G4 with low pressure drop + folded opacimetric filters F7 4 4 Double stage of folded opacimetric filters:M6+F7; F7+F9 4 4 Outdoor fan 12 Axial 2-speed outdoor fan directly coupled to the motor 4 Insulation 13 Thermal and acoustic insulation, Euroclass A2-s1, d0 (M0), with double wall (50mm) 4 Indoor unit 14 Condensate drain pan in stainless steel 4 4 Differential pressure switch to detect clogged filters 4 Management of the overpressure 4 4 Outdoor unit 15 Fresh air intake protection grid 4 4 Outdoor coil protective grille 4 4 Stop-drop at the fresh air intake 4 4 Antivibration mounts made of rubber 4 4 Passive recov. 16 Rotary heat exchanger characteristics: diameter, channel cross section and wheel material, type of speed control 4 Extra heating 17 Heat recovery coil 4 Special 18 Air zoning 4 (*) applications Low return temperature application 4 Low return temperature application + Air zoning 4 Sensors 19 Ambient temperature sensor: one NTC sensor connected to the control board or 1 to 4 RS485 sensors 4 4 Ambient temperatute + humidity sensor: one to four sensors with RS485 communication 4 4 Air quality sensor: ambient installed, return (duct-mounted), on a pLAN local network or double sensor (ambient + 4 4 ambient; ambient + outdoor; return + outdoor) Smoke detecting station in accordance with the NF S 61-961 standard 4 4 Free-cooling + 20 Type of free-cooling: thermal, enthalpic or thermoenthalpic 4 4 Outd. humidity Outdoor air humidity sensor: supplied with the unit or installed on a pLAN local network 4 4 Terminal + Unit 21 TCO terminal installed in the electrical cabinet 4 4 communication VecticGD terminal installed in the electrical cabinet + TCO terminal remote up to 100m 4 4 TCO terminal installed in the electrical cabinet + VecticGD terminal remote up to 200m 4 4 VecticGD terminal installed in the electrical cabinet + VecticGD terminal remote up to 200m 4 4 Unit configuration: stand-alone, master or slave 4 4 Communication cards: RS485 Modbus/Carel; Ethernet PCoWeb; RS485 LonWorks®; Ethernet BACnet ; RS485TM BACnet ; RS485 KonnexTM 4 4 Miscellaneous 22 Management of an humidifier with proportional or on/off control 4 item 1 Energy meter 4 Energy meter and calculation of the cooling and heating capacities 4 Refrigerant leak detector 4 Miscellaneous 23 Tropicalized components on the electrical cabinet: control board, cards and terminals 4 item 2 High performance phase monitoring relay 4 4 Return fan 24 Centrifugal return fan: 3 airflow options: low, nominal and high 4 Return plug-fan: 3 options depending on the available pressure: nominal pressure (Polypropylene), nominal pressure 4 (Aluminium) or high pressure (Aluminium) Airflow 25 There are 9 combinations in the direction of air with: direction - Supply: lower, lateral and upper 4 - Return: lower, lateral and upper Roofcurb -- Standardised pre-assembly roofcurbs with adjustable height 4 Adaptation roofcurbs for replacing units on site 4 4 (*) The rotary heat exchanger (CW and CL assemblies) and part of the air zoning option are supplied disassembled with the unit, for installation on site. 256 256 CATALOGUE 2021