EREBATM eH Pompe à chaleur air/eau réversible tableaUDeseleCtionmoDefroiD EREBA HeTM Température sèche d'air extérieur, °C 5 15 25 EREBATM LWT Pf EER q Pf EER q Pf EER q He °C kW kW/kW l/s kW kW/kW l/s kW kW/kW l/s Nom Min MaxNom Min MaxNomNom Min MaxNom Min MaxNomNom Min MaxNom Min MaxNom 5H 1,07 1,07 1,07 6,72 6,72 6,720,051 2,14 0,91 2,14 4,01 6,07 4,01 0,103 7H 5,44 0,76 5,44 7,5910,747,590,2625,37 0,76 5,37 5,57 7 5,570,2525,60,57 0,59 6,45 3,85 4 3,760,263,25 11H 13,062,5616,026,2412,275,480,62612,393,5713,245,48 7,78 5,18 0,59411,51 3,0513,274,30 4,73 3,880,552 5 2 12,523,61 13,37 5,54 7,86 5,230,60011,623,09 11 HT 13,19 ,5916,18 6,3012,395,540,633 13,40 4,35 4,78 3,91 0,557 15 15,002,5616,025,9512,275,480,70413,243,5713,245,18 7,78 5,18 0,621 13,273,0513,273,88 4,73 3,880,623 15 HT 15,15 2,5916,18 6,01 12,395,540,711 13,373,61 1 5,233,37 7,86 5,230,62813,40 3,0913,40 3,91 4,78 3,91 0,629 5H 1,34 1,34 1,34 7,50 7,50 7,500,0642,42 1,01 2,42 4,59 6,49 4,59 0,116 7H 6,03 0,93 6,03 7,9813,347,980,2835,59 0,95 5,59 6,15 9,55 6,15 0,2756,14 0,77 6,78 4,31 5,62 4,16 0,288 11H 13,922,7817,097,12 12,796,670,66713,19 3,88 14,09 5,64 8,25 5,330,63212,253,38 14,12 4,44 5,18 4,00 0,587 7 11 HT 14,052,8017,267,19 12,926,740,67413,323,9214,23 5,70 8,33 5,390,63912,373,41 14,26 4,48 5,23 4,040,593 15 16,002,7817,096,7512,796,670,751 14,09 3,8814,095,33 8,25 5,330,661 14,12 3,3814,12 4,00 5,18 4,00 0,663 15 HT 16,322,8017,266,8912,926,740,76614,373,9214 ,375,39 8,33 5,390,67514,40 3,41 14,264,04 5,23 4,040,676 5H 1,49 1,49 1,49 8,47 8,47 8,470,071 2,71 1,17 2,71 5,21 7,31 5,21 0,130 7H 6,54 1,01 6,54 8,6417,088,640,307 6,04 1,06 6,04 6,4312,386,430,301 6,79 0,87 6,844,71 7,54 4,540,319 11H 15,293,18 18,789,7614,299,19 0,73314,484,4315,935,95 9,56 5,47 0,69413,453,9515,474,69 6,19 4,220,645 10 11 HT 15,443,2218,979,8514,439,280,74014,624,4716,096,01 9,66 5 ,634,413,5,5 730,701 93,9915 6,26 4,260,651 15 17,583,18 18,789,5514,299,19 0,82515,934,4315,935,47 9,56 5,470,74815,473,95 15,74 224, 6,19 4,220,726 15 HT 17,933,2218,979,6414,439,280,84216,254,4716,255,53 9,66 5,530,763 15,783,99 15,634,62 6,26 4,260,741 5H 3,48 1,41 3,48 6,54 8,46 6,540,167 7H 7,39 1,16 7,39 9,6918,629,690,3476,93 1,25 6,93 7,16 14,51 7,16 0,3457,87 1,05 8,69 5,3410,71 5,12 0,370 11H 5,69 5,69 5,6915,3515,3515,350,27316,655,3718,586,61 14,095,960,79815,494,9418,965,21 9,06 4,37 0,743 15 11 HT 5,75 5,75 5,7515,5015,5015,500,27616,825,4218,766,6814,236,02 0,80615,644,99 19,15 5,26 9,15 4,41 0,750 15 5,69 5,69 5,6915,3515,3515,350,267 18,585,3718,585,96 14,095,960,872 17,774,94 18,964,65 9,06 4,37 0,834 15 HT 5,86 5 5,75 ,8615,501 ,5015,500,2755 18,7654218,766,0, 214,23 6,02089818,304,9919,15 4,70 9,15 4,41 0,859 , 5H 5,30 1,56 5,30 6,73 9,63 6,73 0,254 7H 8,20 2,85 8,2010,5419,5810,540,3857,74 1,67 7,74 7,8016,077,800,3869,05 1,46 9,71 5,7312,825,480,425 11H 5,99 5,99 5,9917,9617,9617,960,28717,835,81 19,907,0616,226,340,85516,595,41 2005,55,3 1 792,184,61 0, 5 18 11 HT 6,05 6,05 6,0518,1418,1418,140,29018,01 5,8720,10 7,13 16,386,400,86316,755,462005,60,5 1 12,3 4,66 030,8 15 5,99 5,99 5,9917,9617,9617,960,28719,905,81 19,906,3418,256,340,93419,025,41 2004,91,3 1 92,184,61 0,83 15 HT 6,05 6,05 6,0518,1418,1418,140,29020,10 5,8720,10 6,4018,436,400,96219,595,462004,96,5 1 12,3 4,66 200,9 Legend Données d'application LWT Température de sortie d'eau, °C Unités standard, réfrigerant: R-410A Pf Puissances frigorifique kW Différence de température d'entrée ou de sortie d'eau du condenseur: 5 K Nom Nominal Fluide du condenseur: eau Min Minimum Coefficient d'encrassement: 0 m² kW Max Maximum Performances établies selon EN 14511 EER Coefficient de performance, kW/kW q Débit d'eau à l'évaporateur, l/s 322 322 CATALOGUE 2021